H A N D M E S S G E R Ä T PORTABLE DATA RECORDER APPAREIL DE MESURE PORTABLE H M G 5 1 0 Stock no.: 669730 Ed

Página 2

10 Operating the HMG 510 Using HSI Sensors Min/Max Function The HMG 510 records the minimum and maximum values in addition to the current measured v

Página 3

11The time period always begins when the min/max values are reset. Resetting the values is prompted by the following situations: • Switching the un

Página 4 - Connecting HSI Sensors

12 Measured Value Differential You also have the option of measuring and displaying a value differential between channel A and B. The channel A–B dif

Página 5 - Connecting SMART Sensors

13Setting the Zero Point The Tare function enables you to rezero measurement channels. This function is used to mask out backpressure buildups presen

Página 6 - Technical Safety

14 All measurement channels which have been rezeroed are designated by a blinking measurement unit for safety reasons (see screenshot). Caution! A

Página 7 - About Your HMG 510

15Menu Structure and Navigation of the HMG 510 The menu structure and navigation of the HMG 510 vary depending on the number and type of sensors conn

Página 8 - Connectors

16 Menu Structure and Navigation When Using One Sensor Nutshell description Mode Menu item Function description 1x SEnA unIT Select the unit of mea

Página 9

17 • Mode Press 3x Setting aid for mechanical pressure switches For more information, please refer to Setting Aid for Mechanical Pressure Switches s

Página 10 - Min/Max Function

18 Menu Structure and Navigation When Using Two Sensors Nutshell description Mode Menu item Function description 1x SEnA unIT Select the unit of me

Página 11

19 • Mode press 5x Computing a differential from tare values Computes the difference between two tare values. • Mode press 6x Setting aid for mech

Página 12 - Measured Value Differential

2 Table of Contents Table of Contents 2 Tasks and Functions of the HMG 510 4 Designated Tasks 4 Connecting HSI Sensors 4 Connecting SMART Sensor

Página 13 - Setting the Zero Point

20 Power supply Y adapter Operating the HMG 510 Using SMART Sensors SMART sensors are a new generation of sensors from HYDAC, capable of outputting

Página 14 - Measurement

21Rendering and Modification of the Measured Value Display The first measured value appears in the display of the HMG 510. The unit of measurement ap

Página 15 - Navigation of the HMG 510

p Hydraulicpressure unit Mechanical pressure switch22 Setting Aid for Mechanical Pressure Switches To use the HMG 510 as a setting aid for mechanic

Página 16 - Nutshell description

23Items Shown in Display The status display items are located in the lower right corner: • Current status of the mechanical pressure switch: 0 = ope

Página 17

24 Technical Specifications Sensor inputs The HMG 510 features two analog inputs with automatic sensor detection at 2 input jacks (channel A and B).

Página 18

25Accessories • Pressure transmitters 1 – 9 bar, 0 – 16 bar, 0 – 100 bar, 0 – 250 bar, 0 – 400 bar, 0 – 600 bar Stock no. 909429 Stock des. HDA 474

Página 19

26 HYDAC ELECTRONIC GMBH Hauptstr. 27 D-66128 Saarbrücken Germany Phone: +49-(0)6897-509-01 Fax: +49-(0)6897-509-1726 HYDAC Service For repair

Página 20 - Connection diagram

3Operating the HMG 510 Using SMART Sensors 20 Connection diagram 20 Rendering and Modification of the Measured Value Display 21 Operating the HMG

Página 21

4 Tasks and Functions of the HMG 510 Designated Tasks The HMG 510 Portable Data Recorder is a hand-held unit for simple measurement tasks on hydrauli

Página 22

5Connecting SMART Sensors SMART sensors are one of the new generation sensors from HYDAC, capable of outputting up to 10 different measured variable

Página 23 - Items Shown in Display

6 Technical Safety The individual components of the HMG 510 Portable Data Recorder and the assembled unit are subject to strict quality assurance ins

Página 24 - Technical Specifications

7 General Safety Information The HMG 510 series Portable Data Recorder can be operated safely provided it is used in accordance with its proper, desi

Página 25 - Accessories

9 76 8 (+)(-)2 1 3 4 5 8 Starting the HMG 510 Up Operating Keys 1 On/Off button 2 Mode — for setting the menu 3 Reset For resetting the min/max v

Página 26 - HYDAC SERVICE GMBH

9Operating Instructions General Operating Information If other sensor makes are connected to the HMG 510, the following message appears in the displa